Business block

Industrial mine
Industrial mine
Detonator series
Contact

Technical Parameter

Item

Performance

Resistance

Galvanized steel core leg wire ≤6.3Ω, Range ≤2.0Ω

Safety current

Charging with 0.2A    constant direct current for 5min, no explosion.

Minimum firing current

≤0.45A

Firing impulse

2.0~7.9A2·ms

Series firing current

Connect 20 pieces of electric detonators    into series and charge with 1.2A    constant direct current, all detonators explode.

Initiating Power

Have a 5mm    lead plate test, and the hole diameter will not be smaller than the detonator    outer diameter.

Tensile

Charged with 19.6N static tension for 1min, no damage and removal to    the sealing and leg wire.

Anti-jolt property

No explosion, structure damage,    short circuit, open circuit and unstable performance after vibrating for    10mins.

Anti static

Leg wire to shell discharge with 8kV voltage, 2000pF capcitance and    0Ω series resistor, no firing.

Combustible gas safety degree

When initiating a permissible electric    detonator in the combustible gas of 9% thickness, the combustible gas should    not be initiated.


Technical Index:

Specification: Industrial No.8

Shell outer diameter: Φ6.9mm

Shell:Flange

Shell length:50~70mm

Leg wire: Galvanized steel, copper,copperclad steel

Leg wire length: 2m(can be ensured according to the requirements of

customers)

Igniter element: Elastic fuse head,rigid fuse head