Item | Performance |
Resistance | Galvanized steel core leg wire ≤6.3Ω, Range ≤2.0Ω |
Safety current | Charging with 0.2A constant direct current for 5min, no explosion. |
Minimum firing current | ≤0.45A |
Firing impulse | 2.0~7.9A2·ms |
Series firing current | Connect 20 pieces of electric detonators into series and charge with 1.2A constant direct current, all detonators explode. |
Initiating Power | Have a 5mm lead plate test, and the hole diameter will not be smaller than the detonator outer diameter. |
Tensile | Charged with 19.6N static tension for 1min, no damage and removal to the sealing and leg wire. |
Anti-jolt property | No explosion, structure damage, short circuit, open circuit and unstable performance after vibrating for 10mins. |
Anti static | Leg wire to shell discharge with 8kV voltage, 2000pF capcitance and 0Ω series resistor, no firing. |
Combustible gas safety degree | When initiating a permissible electric detonator in the combustible gas of 9% thickness, the combustible gas should not be initiated. |
Technical Index:
Specification: Industrial No.8
Shell outer diameter: Φ6.9mm
Shell:Flange
Shell length:50~70mm
Leg wire: Galvanized steel, copper,copperclad steel
Leg wire length: 2m(can be ensured according to the requirements of
customers)
Igniter element: Elastic fuse head,rigid fuse head